|
|
|
 |
KDP-24B |
|
 |
Complete sealing structure : Completely sealed and has excellent resistance to oil and water. Minimum Wiring : While multi-stage rotary switch combines the code in a complicated wiring, our wiring is simplified and connect the connector by using digital code system. 15˚ / REAL BINARY CODE / 7pin Standard type * Please refer to user manual.
|
Quantity : 1 |
Title : |
|
|
 |
|
|
 |
Model |
KDP-24B |
15˚ / REAL BINARY CODE / 7pin Standard type |
|
|
Product catalogue |
dwg |
 |
 |
|


① |
Step angle |
12 |
30˚ |
24 |
15˚ |
② |
Code |
A |
Complement binary code |
B |
Real binary code |
G |
Real gray code |
③ |
Pin number |
None |
7pin |
F |
8pin |
④ |
Terminal type |
None |
Standard type |
C |
Connector type |

1. Complete sealing structure
Completely sealed and has excellent resistance to oil and water.
2. Minimum wiring
While multi-stage rotary switch combines the code in
a complicated wiring, our wiring is simplified and connect
the connector by using digital code system.
3. Simple change of setting value
Setting value can be changed simply in SELF-TAPPING.
4. Adopt contact point made of gold
Maintain stable friction resistance with double slide contact point
and have high reliability.
5. Type of code
3 Code type : complement binary, real binary, Real gray code,
Available angles in 2 types: 15°, 30°
6. Prevent wrong signal
Inhibit terminal or parity terminal are set depending on the code.
|

1. Operating Temperature : -20℃~+70℃
2. Rotational torque : 0.1~0.2N·m(1~2kgf·cm)
3. Friction resistance : DC 5V 1A resistance of below 100㏁
4. Insulation resistance :
DC 250V / After 1min / Terminal to terminal / 500㏁≤
DC 500V / After 1min / Terminal to ground / 25V 0.1A
5. Rating :
Resistance load
AC 5V 0.5A 48V 0.05A
DC 5V 0.25A 25V 0.05A
6. Service life : 70,000 operations
* COMPLEMENT BINARY CODE
* REAL BINARY CODE
* REAL GRAY CODE
Model |
step angle |
Code |
Pin number |
Standard type |
Connetor type |
30° |
15° |
Complement binary |
Real binary |
Real gray |
7pin |
8pin |
KDP-12A |
● |
|
● |
|
|
● |
|
● |
|
KDP-12B |
● |
|
|
● |
|
● |
|
● |
|
KDP-12G |
● |
|
|
|
● |
● |
|
● |
|
KDP-24A |
|
● |
● |
|
|
● |
|
● |
|
KDP-24B |
|
● |
|
● |
|
● |
|
● |
|
KDP-24G |
|
● |
|
|
● |
● |
|
● |
|
KDP-12AF |
● |
|
● |
|
|
|
● |
● |
|
KDP-12BF |
● |
|
|
● |
|
|
● |
● |
|
KDP-12GF |
● |
|
|
|
● |
|
● |
● |
|
KDP-24AF |
|
● |
● |
|
|
|
● |
● |
|
KDP-24BF |
|
● |
|
● |
|
|
● |
● |
|
KDP-24GF |
|
● |
|
|
● |
|
● |
● |
|
KDP-12A-C |
● |
|
● |
|
|
● |
|
|
● |
KDP-12B-C |
● |
|
|
● |
|
● |
|
|
● |
KDP-12G-C |
● |
|
|
|
● |
● |
|
|
● |
KDP-24A-C |
|
● |
● |
|
|
● |
|
|
● |
KDP-24B-C |
|
● |
|
● |
|
● |
|
|
● |
KDP-24G-C |
|
● |
|
|
● |
● |
|
|
● |
KDP-12AF-C |
● |
|
● |
|
|
|
● |
|
● |
KDP-12BF-C |
● |
|
|
● |
|
|
● |
|
● |
KDP-12GF-C |
● |
|
|
|
● |
|
● |
|
● |
KDP-24AF-C |
|
● |
● |
|
|
|
● |
|
● |
KDP-24BF-C |
|
● |
|
● |
|
|
● |
|
● |
KDP-24GF-C |
|
● |
|
|
● |
|
● |
|
● |
■ Specifications and standards are subject to change without prior notice.
|

When you adjust the stages, put the bolt stopper pin in the hole representing A, B, C and so on.
Example) 30°switching |
8 stages set-up (0~8) |
START : 0 → A END : 8 → S |
11 stages set-up (0~11) |
START : 0 → A END : 11 → A |

Example) 15°switching |
22 stages set-up (0~22) |
START : 0 → A END : 22 → NONE |
23 stages set-up (0~23) (360°rotating) |
START : 0 → A END : 23 → NONE |


Warning
- When it used in a machine that might cause accidents of worker or enormous property damage,
It should be used after the double safety device is attached.
- If it is used with the voltage other than the designated one,
it might cause injury for human and property damage.
- Before turning on the power, make sure whether the wires are connected correctly.
- Do not disassemble, process, remedy or repair this product in any case,
because it might cause malfunctioning.
|

Development through ceaseless technology development and value creation KEM Co., Ltd.
 |
|
|
CE certificate [2013.12] |
|
|
 |
|
|
|
|
|
|